For Magnetic Drive Pump

Unable to Discharge Liquid:
What would be happened on pump Causes Remedy
When the valve is closed When the valve is opened
  Pressure and vacuum gauge points to 0
  • Insufficient water for starting the pump
  • Dry run
  • Shut down the pump. Then re-start the pump with sufficient water 
The water level in the suction pipe keeps reducing  
  • Foreign objects go into check valve
  • Clean the filter mesh
  • Check if any foreign objects go into the check valve
When pump starts to operate, no discharge volume  The indicator of pressure and vacuum gauge goes down to 0
  • Air goes into the pipe
  • Inspect is there any leak in the suctional pipe
  • Inspect is the liquid level over-low
  • Demagnetized
  • Shut down the pump, then check the fan of motor if it runs easily
  • Check is the current over load  
  • Check is there any foreign objects between impeller and driven magnetic
  • Check is the voltage correct
Insufficient Discharge Volume:
What would be happened on pump Causes Remedy
When the valve is closed When the valve is opened
Low pressure  
  • Insifficient rpm. 
  • Pump rotation reversed
  • Inspect the wiring and motor
  • Correct the wiring
  High vacuum pressure
  • The suction filter clogged
  • Clean the suction filter
  Over-high vacuum pressure
  • There is air in the suction pipe
  • Correct the installation of suction pipe
   
  • The entrance of impeller is clogged by foreing objects
  • Remove the foreign objects
Normal pressure and vacuum pressre The indicator of pressure and vacuum gauge keeps shaking
  • Air goes into the pipe
  • Tighten the connect part of suction pipe
 
  • The discharge is clogged by foreing objects
  • Remove the foreign objects in the pump
  • Remove the foreign objects in the piping
High vacuum pressure and normal pressure
  • There is air or other resistance in the suction pipe
  • Inspect the suction pipe
Low vacuum pressure and pressure High pressure and normal vacuum pressure
  • There is resistance in the discharge pipe
  • Inspect the discharge pipe
Over-high Motor Temperature:
What would be happened on pump Causes Remedy
When the valve is closed When the valve is opened
   
  • Pump rotation reversed
  • Insifficient Voltage
  • Motor overload
  • High surrounding tepmerature
  • Correct the wiring
  • Inspect is the voltage and frequency right
  • Inspect is the S.G and viscosity of liquid proper
  • Shut down the pump, then check the fan of motor if it runs easily
  • Keep surrounding in good ventilation
Discharge Volume Decline Rapidly:
What would be happened on pump Causes Remedy
When the valve is closed When the valve is opened
  High vacuum pressure
  • The suction filter clogged
  • Remove the foreign objects
High noise level and vibration:
What would be happened on pump Causes Remedy
When the valve is closed When the valve is opened
   
  • Bad installation
  • Loose bolts
  • The suction pipe clogged
  • The bearing worn
  • The spindle broken 
  • Bad dynamic balance of drive magnet
  • Motor bearing worn
  • Re-install the pump
  • Tighten the bolts
  • Remove the foreign objects
  • Replace the bearing
  • Replace the spindle 
  • Remove te drive magnet
  • Replace the motor or motor bearing